Check wheather the user is having the proper authorization or not?? Just check in the SU53 report
Re: Issue in UWL
Re: IWO10027 not triggering
Hi ,
Thanks for Reply ,I have created Project and try to trigger but not working .
Re: PM notification auto release
Hello experts,
please help me out from this case.
Thanks in advance
Regards,
Toshit Chaudhari
Re: Customer Exit for Prior day using 0calday
Hi AL,
Yes, We may write look up in transformations taking a separate field for Qty Prior Day and write code for this. Can you please help to write code actual logic to get value for corresponding calday.
Just provide some example code so that I can write.
Thanks,
Rahul
Re: Alignment changes in SAP SCRIPT output?
Hi,
have you created script in Arabic language, if yes then change it to English then you will be able to get LTR alignment.
thanks!!
Cash discount to customer
Dear All,
We have configured for calculating cash discount and which will post automatically when we post the collection entry thru F-28.This is happening also.
Now we have some issues with regards to that.
1.If a customer pays advance and then material sent to him later he is also eligible for cash discount.In this case we can not post the advance collection entry thru F-28 for posting the cash discount because invoicing is not done at that time.So how to post cash discount in this scenario.
2.A sales invoicing is made on 30.12.2015 for Rs.100000 for which due date is 05.01.2016.Customer has made payment thru two cheques separately on 01.01.2016 and 03.01.2015 Rs 50000 each. in this case how to post cash discount automatically..
3.If the collection amount is more than the invoice amount which is eligible for cash discount.
in this case how to post cash discount automatically..
Regards,
Shivaji
Re: Search help PREM does not exist in AS02
Hello Tanu Shree,
Did you get solution for the issue you face with Search help PREM does not exist?
Re: Is it possible to use RFC look up and Multi mapping in NW BPM
as per above diagram , i guess you no need to go for NWBPM.
you just think about either enhance receiver determination or Interface determination.
if you want go enhancement receiver determination you should create 2 partys(one for idoc and another for RFC) to determine the currect reciver to sent IDOC or RFC , since you have single ECC to send Either Idoc or RFC
Re: GUI setup error: Could not connect to host localhost on port 21212
Hi Andre,
What about the second entry i.e for system IP with hostname ? Please maintain it also as suggested earlier.In resume reconfirm for the firewall disability to try again.
Regards,
Re: No authorization for the project in LSMW
Hi Martina and Sriram,
Thank you for the helpful transaction. I tried SU53 but the missing authorization object is not relevant to the issue she had .
Regards,
Danny
Re: No authorization for the project in LSMW
Hi Marcel,
Thank you for the suggestion. Those S_BTCH* and S_BDC_MONI objects sound reasonable. I will add those objects to the role and will ask her to try again.
Thanks,
Danny
Re: DataServices and SQL 2014 Query issues
Can you check if the Source table has constant records or is it getting updated daily/hourly
Can you extract data for a specific Month or day and check by applying the filter in the where tab of Query transform
Also post the screenshot of the the SQL under Validate>Display Optimized SQL
Regards
Arun Sasi
Create new Freight order through Freight unit
Hi ,
In BOPF using OPTIMIZE action in /SCMTMS/TOR object I have to create the Freight Order using multiple Freight Units having the same stages but FO is not created and not populating any errors.
In this FU's are not planned , Here is the sample code I wrote to create the FO
lo_srv_mgr TYPE REF TO /bobf/if_tra_service_manager, " Containing the public service methods of a service manager
&---------------------------------------------------------------------*
* Get an instance of a service manager for FO
*&---------------------------------------------------------------------*
lo_srv_mgr = /bobf/cl_tra_serv_mgr_factory=>get_service_manager( /scmtms/if_tor_c=>sc_bo_key ).
CALL METHOD
lo_srv_mgr->do_action
EXPORTING
iv_act_key = /scmtms/if_tor_c=>sc_action-root-optimize
it_key = lt_key_fu
* is_parameters =
IMPORTING
eo_change = lo_change
eo_message = lo_msg
et_failed_key = lt_failed_key
et_failed_action_key = lt_failed_act_key
.
IF lo_msg IS BOUND .
/scmtms/cl_common_helper=>msg_convert_bopf_2_bapiret2(
EXPORTING
io_message = lo_msg
CHANGING
ct_bapiret2 = lt_bapiret2 ).
endif.
*&---------------------------------------------------------*
* Save the changes on the Freight Order/Freight bookings..
*&---------------------------------------------------------*
lo_tra->save( IMPORTING eo_message = lo_msg ).
IF lo_msg IS BOUND .
/scmtms/cl_common_helper=>msg_convert_bopf_2_bapiret2(
EXPORTING
io_message = lo_msg
CHANGING
ct_bapiret2 = lt_bapiret2 ).
endif.
Please suggest an alternative if it doesn't work this way.
Thanks
Arun
Re: configuration of ITSM
Hello Saqlain,
If you current requirement is atleast addressed to some extent...then please close this thread and open new thread with whatever question you have. That will give you faster responses.
Standard SAP Complete configuration specific document are available online.
If you are looking for specific queries....we are all here to help.
Regards
Anand
WCM on Maintenance order
Hi... Experts ,
client want Permit option should be optional at the time of creating maintenance order.
in WCM we have already assigned the permit to the technical object, so whenever any maintenance order created with the same technical object, system will prompt the Work permit button on the header of Maintenance order.
because permit is not require for every work.
Please suggest your expert comment on the same
Re: No authorization for the project in LSMW
Check authorization object S_BDC_MONI to process session in background.
Authorization field BDCAKTI = ABTC
Re: GUI setup error: Could not connect to host localhost on port 21212
Now it looks like:
127.0.0.1 localhost.localdomain localhost
::1 localhost.localdomain localhost
But will also not work.
But for better understanding please - as I describe netstate will not show any service listen at 21212.
So how could be connection to 21212 possible without any listener?
Re: GUI setup error: Could not connect to host localhost on port 21212
MSS Home Page _ Organization view not found
Dear experts,
the MSS role Home page was working fine on Development when configuration transported to quality system i face this error.
kindly check the screen shots attached and please help tracing the issue as it's urgent
thanks alot,
Mohamed Mohsen
Re: Erro 699 - Sefaz PE
José
Veja se isso ajuda
(Rejeição 699 NFe - NT2015-03 - SPED Brasil)
(NF-e NT 2015.003 versão 1.40 - EC 87-15 - DIFAL - GNRE - CEST - SPED Brasil)
Ajusta o XML e usa o Validador RS para verificar se corrigiu o problema.
Att
RONALDO